GONOTEC OSMOMAT 030 PDF

Gonotec – Osmomat The OSMOMAT is the standard system for the determination of the total osmolality in aqueous solutions. This system is commonly. Gonotec Gesellschaft für Meß- und Regeltechnik mbH does not assert any claim on trademarks or trade names other than its own. ® OSMOMAT model. Find pricing on new and used Gonotec Osmomat ‘s and other lab products. Connect with a variety of sellers on LabX and buy today.

Author: Maran Voodoonris
Country: Yemen
Language: English (Spanish)
Genre: Health and Food
Published (Last): 17 July 2018
Pages: 309
PDF File Size: 8.91 Mb
ePub File Size: 15.79 Mb
ISBN: 859-3-36578-238-4
Downloads: 77359
Price: Free* [*Free Regsitration Required]
Uploader: Maulrajas

The Gonotec Chloridmeter is also available, with the ability to take vital sweat measurements for cystic fibrosis testing.

Gonotec Osmomat Cryoscopic Osmometer

Correct feed direction for paper roll Printer paper PU 8 Order No. Always use a new measuring vessel with fresh distilled water for each new measurement.

We are no anonymous, large concern, but we do know our customers personally, their problems and tasks and the herefrom resulting requirements for us and The output voltage of the analog output can be aligned with the alignment potentiometer for older flatbed recorders. The measuring vessel holder is lowered and the cooling process begins.

Gonotec Osmomat Cryoscopic Osometer The failure of individual functional groups in the unit results in a malfunction that either reports an error message or shuts down the unit.

  FRESHKILLS PARK PDF

Gonotec Osmomat 030 Cryoscopic Osmometer

The purpose of the adjustment is align the center axis of the cooling clamp with the thermistor axis see Figure 7: You will feel a slight resistance and hear a click. The OSMOMAT obtains a reading for the total osmolality by calculating the temperature difference between the freezing point of the water and the reversal point detected while measuring the sample solution.

Alphanumeric dot matrix printer, 5×7 matrix, date, time of each measurement Number of digits: Monday, 20 September, Supplied by: The packaging is re-usable. Oemomat port for continuous recording of the temperature development with a compensating recorder.

Do not run the initial measurement until at least two minutes have elapsed after the unit was switched on. These operating instructions help you gain a basic understanding of the design, gonottec measurement principle, maintenance and servicing of the unit.

Gonotec Osmomat For Sale | Labx

Mounting screws Figure 8: Remove the adjustment tool and re-attach the upper cooling system cover with its two screws. The Gonotec limited warranty gonootec applicable in all countries in which Gonotec sells the applicable product. The end of the paper must be between the ribbon and the cartridge. A sequential number is printed out along with the measurement results. Compliance is declared per Annex III. Provisions of Certification CE compliance requires that the unit be installed and operated in the manner described in this manual.

  EDITAL DO CONCURSO DATAPREV 2012 PDF

The following countries and regions are excepted: Attention refer to documentation!

A shows a setting for V. Calibration at three points.

How virtual reality can change the way we see our molecular world. Use a soft paper towel to thoroughly clean the thermistor probe after each measurement. A wide range of options and accessories are available to allow the user to configure the system to meet the specific needs of the laboratory. Rear view of the Osmomat Following calibration, a control measurement with the calibration gonotfc or a solution of known osmolality should confirm the exact 2 setting.

Symbols on the unit and its nameplate correspond to the requirements of the following standards: Limitations of Liability To the extent permissible under the applicable local laws, the legal remedies named here shall be the sole and exclusive legal remedies available to the customer.

Any departure from the specifications or independent modifications of the unit without the express consent of Gonotec GmbH may result in a violation of CE requirements. This will destroy the measurement system.